One of the key objectives of BEEP is to help Indian builders and developers in adopting new processes, tools and technologies for designing energy-efficient buildings. BEEP provides the expertise of senior Swiss and Indian architects and engineers to assist in developing the energy concept for selected commercial design projects, promoted by private and public sector builders and developers. The support that BEEP offers includes conducting an integrated design charrette (4 day design workshop) and continued technical support till the schematic design is achieved.

Till November 2013, 6 commercial building projects (6 private sector and 2 public sector projects) were selected for the charrette assistance. BEEP provided technical inputs through charrette for improving their energy performance by 25 - 47%.

Cover Image: 
Release Date: 
12 Mar, 2014
Integrated Design Charrette for IIIDEM in Noida
Uploaded Date: 
06 Jul, 2017

Project Snapshot 
Built-up area: 26,240 m2
Climate type: Composite

Strategies recommended during the charrette

  • Dry stone cladding with air gap and insulated glazing to reduce heat gain inside the building.
  • Non-occupied spaces (like staircase, machine rooms, toilets etc.) on the south-west face of the block.
  • Free cooling, incorporating the use of ambient air for cooling whenever suitable.
  • Heat recovery wheel (effectiveness 75%) to reduce the energy consumption for cooling the fresh air.
  • Use of high performance water cooled chillers with better part load performance instead of air-cooled chillers. Automated control on the chiller to raise the chilled water temperature (gliding chilled water temperature) as per the cooling load.
  • Solar hot water generation for kitchen.
  • Renewable electricity generation through roof-top solar photovoltaics
Integrated Design Charrette for Jupiter Hospital in Pune
Uploaded Date: 
06 Jul, 2017

Project Snapshot 
Built-up area: 26580 m2
Climate type: Warm and Humid

Strategies recommended during the charrette

  • 150 mm AAC (Autoclaved Aerated Concrete) blocks was proposed to replace 230 mm brick wall
  • Roof insulation of 100 mm extruded polystyrene was proposed for uninsulated roof
  • Proposed high performance glazing for windows in place of double clear glass
  • Installing the heat recovery wheel of effectiveness of 0.75 (sensible and latent) in all AHU units
  • Free cooling the zones whenever outside temperatures are below set point temperatures
  • Gliding the chilled water temperature at part loads + Energy Efficient chiller selection
  • Using condenser water to reheat the supply air where reheat units are provided
Integrated Design Charrette for Information Technology Park in Haryana
Uploaded Date: 
13 Mar, 2014

Project Snapshot
Built-up area: 71,500 m2
Climate type: Composite

Strategies recommended during the charrette

  • Free cooling for ventilation
  • Utilizing DG exhaust for cooling through VAM (vapour absorption machine)
  • Integration of photovoltaic
Integrated Design Charrette for Information Technology Park in Madhya Pradesh
Uploaded Date: 
13 Mar, 2014

Project Snapshot
Built-up area: 100,000 m2
Climate type: Composite

Strategies recommended during the charrette

  • Microclimate development to reduce heat island effect
  • Orientation and solar protection
  • Reorganization of spaces for daylighting
  • Thermal inertia
  • Free cooling and night cooling Indirect adiabatic two-stage evaporative cooling
  • Efficiency of axial fan at cooling tower
  • Lower pressure losses in hydronic circuits
  • Energy efficiency measures for chillers
  • Chilled beams with dedicated outdoor air system
  • Hydronic free cooling with passive chilled beams
Integrated Design Charrette for Public Office Building in Karnataka
Uploaded Date: 
13 Mar, 2014

Project Snapshot
Built-up area: 80,000 m2
Climate type: Moderate

Strategies recommended during the charrette

  • Façade orientation, window and shading design
  • Maximizing daylight in the office area
  • Improving the quality of space
  • Thermal inertia
  • Low energy seasonal cooling strategies
  • Energy efficiency measures for chillers
  • Gliding temperature at evaporator and condenser of chillers
  • Variable speed drives on chillers
Integrated Design Charrette for Private Office Building in Karnataka
Uploaded Date: 
13 Mar, 2014

Project Snapshot
Built-up area: 65,000 m2
Climate type: Moderate

Strategies recommended during the charrette

  • Analysis of photovoltaic canopy potential for on-site solar electricity production
  • Strategies of efficient façade
  • Use of efficient lighting fixtures, daylight integration, and best practices
  • Use of efficient chillers at part load
  • Dedicated dehumidification chillers for fresh air and seprate chiller with elevated chilled water temperature (12 °C) to meet space sensible load
  • Free cooling and night ventilation
  • Gliding temperature at evaporator and condenser of chillers
  • Variable speed drives on chillers
Integrated Design Charrette for Public Office in Rajasthan
Uploaded Date: 
13 Mar, 2014

Project Snapshot
Built-up area: 14,000 m2
Climate type: Composite

Strategies recommended during the charrette

  • External wall insulation to meet ECBC (Energy Conservation Building Code) norms
  • Efficient glazing to meet ECBC norms
  • Roof insulation to meet ECBC norms
  • High efficiency water-cooled chillers
  • Reorganization of spaces to maximize daylighting
  • Natural ventilation and passive downdraft evaporative cooling in the common area
  • Reduction in glazed area in the common core Integration of solar photovoltaic
  • Solar water heater for guest house
Integrated Design Charrette for Commercial Development in Maharashtra
Uploaded Date: 
13 Mar, 2014

Project Snapshot
Built-up area: 23,000 m2
Climate type: Warm and humid

Strategies recommended during the charrette

  • Insulation on the roof
  • Photovoltaic canopy at the terrace
  • External movable blinds southern and northern façades of office towers with light shelves and operable windows for ventilation
  • Fixed shading devices for the eastern and western façades of lower levels
  • Efficient glazing
  • Natural ventilation and night cooling
  • Water-cooled split DX system instead of air-cooled systems
  • Centralized water-cooled systems
  • Indirect evaporative cooling for fresh air in common spaces
Uploaded Images: 